Cheat sheets

AP Chemistry / Chapter 5

Kinetics

Cheat sheet

Measuring reaction rates

  • Average disappearance =−Δ[A]/Δt=-\Delta[A]/\Delta t normalize by stoichiometric coefficients.
  • Instantaneous rate is a tangent slope; isolate variables experimentally.

Experimental rate laws

  • r=k[A]m[B]nr=k[A]^m[B]^n determine exponents from controlled trials.
  • Overall order is the exponent sum; k units depend on order.
  • For overall order pp [k]=M1−ps−1[k]=\mathrm{M}^{1-p}\mathrm{s}^{-1} when rate is measured in molarity per second.

Integrated rate laws

  • Zero order: [A]t=[A]0−kt[A]_t=[A]_0-kt First order: ln⁡([A]t/[A]0)=−kt\ln([A]_t/[A]_0)=-kt
  • Second order k[A]2k[A]^{2} 1/[A]t=1/[A]0+kt1/[A]_t=1/[A]_0+kt
  • First-order t1/2=0.693/kt_{1/2}=0.693/k
  • Zero-order t1/2=[A]0/(2k)t_{1/2}=[A]_0/(2k) second-order t1/2=1/(k[A]0)t_{1/2}=1/(k[A]_0) for r=k[A]2r=k[A]^2 First-order half-life is independent of starting concentration.

Mechanisms and activation energy

  • Profile: barriers are measured from the starting state; reaction coordinate is not time.
  • Mechanisms must reproduce both stoichiometry and the rate law.
  • Catalysts change pathways, not equilibrium constants or reaction enthalpy.
  • k=Ae−Ea/(RT)k=Ae^{-E_a/(RT)} ln⁡(k2/k1)=−(Ea/R)(1/T2−1/T1)\ln(k_2/k_1)=-(E_a/R)(1/T_2-1/T_1) Use kelvin and compatible energy units.

Diagrams

Integrated rate laws
Zero-order concentration versus time is linear with negative slope. First-order natural log concentration versus time is linear with negative slope. Second-order reciprocal concentration versus time is linear with positive slope. These are transformed schematic plots, not three curves on one shared scale.
Zero-order concentration versus time is linear with negative slope. First-order natural log concentration versus time is linear with negative slope. Second-order reciprocal concentration versus time is linear with positive slope. These are transformed schematic plots, not three curves on one shared scale. Source
Mechanisms and activation energy
Two schematic pathways have the same reactant and product energies. The catalyzed pathway has a lower maximum, so its forward activation barrier is smaller. The products lie lower than reactants in this exothermic example; the horizontal coordinate is reaction progress, not time.
Two schematic pathways have the same reactant and product energies. The catalyzed pathway has a lower maximum, so its forward activation barrier is smaller. The products lie lower than reactants in this exothermic example; the horizontal coordinate is reaction progress, not time. Source

Sign in